| date | INES | title | location  |
| 21-04-1996 | INES 1 | Spurious signal for actuation of the ESFAS caused by human error | DUKOVANY-3, Czech Republic |
| 11-01-2024 | INES 2 | Unavailability of Reactor protection system of unit 3 | DUKOVANY-3, Czech Republic |
| 08-07-1996 | INES 1 | Violation of limts and conditions - a late test of spray pumps | DUKOVANY-4, Czech Republic |
| 06-10-1996 | INES 1 | Scram of the reactor caused by a wrong operation of the control room operator | DUKOVANY-4, Czech Republic |
| 31-12-2018 | INES 2 | External corrosion affecting multiple systems on a power reactor | DUNGENESS B, United Kingdom |
| 04-04-2001 | INES 1 | Discovery of an Interlock Defeat applied to the Fuelling Machine d/P/dT Protection system without application | DUNGENESS-B1 UNIT A, United Kingdom |
| 11-07-2003 | INES 2 | Auto-trip of R21, following trip of Main Boiler Feed Pump, subsequent breach of Gas Circulator 22 Inlet Temp. limit | DUNGENESS-B1 UNIT A, United Kingdom |
| 29-06-2009 | INES 2 | Introduction of potentially moderating material to fuel route | DUNGENESS-B1 UNIT A, United Kingdom |
| 19-11-1999 | INES 2 | Discovery of a crack in boiler superheater penetration | DUNGENESS-B2 UNIT B, United Kingdom |
| 12-12-2016 | INES 2 | Inadvertent damage of a Se-75 source | Düsseldorf region, Germany |
| 24-04-2019 | INES 2 | Overexposure of a worker | Eiffage Energie Systeme – Clevia Ouest, France |
| 19-04-2007 | INES 1 | Cs-137 source found in a scrap container prepared for export | El Khaled Scrapyard / Tripoli, Lebanon |
| 18-12-1995 | INES 2 | PRESSURE TUBE FAILURE AND SMALL LOCA IN EMBALSE NPP AFTER GARTER SPRING INSPECTION AND RELOCATION | EMBALSE, Argentina |
| 08-01-1996 | INES 0 | SUDDEN OPENING OF SAFETY STEAM VALVES DURING A ROUTINE TEST OF THE ECCS CONTROL LOGIC, WITHOUT ANY SAFETY-RELATED CONSEQUENCES | EMBALSE, Argentina |
| 30-06-1996 | INES 0 | Slight contamination of potable water due to damage in an auxiliary heat exchanger of the main condenser circuit | EMBALSE, Argentina |
| 31-01-2000 | INES 1 | Loss of power of a 220 VAC safety bus bar | EMBALSE, Argentina |
| 01-07-2003 | INES 1 | Radiological incident occurred in the fuel element auxiliary pool, involving Co-60 withdrawn from an adjuster unit | EMBALSE, Argentina |
| 15-12-2006 | [N/A] | Manual Shutdown at Embalse N.P.P | EMBALSE, Argentina |
| 16-02-2007 | INES 0 | Steam Generator tube leakage at Embalse NPP | EMBALSE, Argentina |
| 15-11-2019 | INES 2 | Radioisotope Manufacture Facility – Operator’s hands contaminated | England, F-18 Cyclotron Facility, United Kingdom |
| 21-03-2001 | INES 0 | EMERGENCY DIESEL GENERATOR BEARING FAILURE & FIRE | ENRICO FERMI-2, United States of America |
| 08-10-1998 | INES 0 | Fire in emergency diesel generator control panel during test | ENRICO FERMI-2, United States of America |
| 05-02-1997 | INES 1 | Supposedly empty shipping containers found to contain nuclear material | ENUSA, Spain |
| 14-09-2022 | INES 1 | Missing Dangerous Source at Estado de Mexico | Estado de Mexico, Mexico |
| 16-10-2000 | INES 1 | Flooding event at the EUREX facility | EUREX, Italy |
| 24-09-2018 | INES 2 | Misdelivered Radioactive Transport Packages | Export packing company in vicinity of Heathrow, United Kingdom |
| 23-11-1992 | INES 2 | CONTAMINATION OF WORKERS DUE TO THE RUPTURE OF A MIXED OXIDE FUEL ROD DURING FABRICATION | FBFC, Belgium |
| 30-12-1992 | INES 2 | PROLONGED LOSS OF VENTILATION IN THE FUEL FABRICATION BUILDING IN THE FBFC ESTABLISHMENT | FBFC, France |
| 13-09-1991 | INES 2 | METALLURGICAL FLAW IN SECONDARY STEAM PIPE | FESSENHEIM-1, France |
| 21-09-2018 | INES 1 | Am-241 source melting | Finnish steel factory, Finland |