date | INES | title | location |
18-01-1992 | INES 1 | AN IMPORTANT LOSS OF COMMUNICATIONS IN MAIN CONTROL ROOM | LAGUNA VERDE-1, Mexico |
22-01-1992 | INES 2 | UNAVAILABILITY OF THE IODINE FILTERING OF REACTOR CONTROL ROOM VENTILATION SYSTEM | DAMPIERRE-1, France |
24-01-1992 | INES 1 | HEAVY WATER LEAK FROM RUPTURED HOSE | RAJASTHAN-2, India |
29-01-1992 | INES 0 | NO IMPACT ON SAFETY FOLLOWING A FIRE IN THE AUXILIARY BUILING OF UNITS 3 AND 4 | KOZLODUY-3, Bulgaria |
31-01-1992 | INES 2 | DETECTION OF A DESIGN ERROR INTHE LEVEL INSTRUMENTATION IN THE ANNULUS OUTSIDE THE CONTAINMENT SPHERE (BETWEEN THE SPHERE AND THE CONTAINMENT BUILDING) | TRILLO-1, Spain |
05-02-1992 | [N/A] | STEAM LEAK AT HIGH PRESSURE TURBINE CAP | KRSKO, Slovenia |
07-02-1992 | INES 2 | TEMPORARY COMPLETE LOSS OF RESIDUAL HEAT REMOVAL | ANGRA-1, Brazil |
12-02-1992 | INES 0 | UNIT-2 REACTOR SCRAM DUE TO GRID DISTURBANCES | TARAPUR-2, India |
03-03-1992 | INES 0 | LOSS OF POWER SUPPLY TO CLASS IV SYSTEMS AND UNIT OUTAGE | KALPAKKAM-1, India |
04-03-1992 | INES 0 | UNIT SHUTDOWN DUE TO FIRE IN THE 6 KV SWITCHGEAR ROOM | BALAKOVO-3, Russian Federation |
18-03-1992 | [N/A] | NO IMPACT TO SAFETY FOLLOWING RUPTURE OF A BYPASS FEEDWATER LINE | KHMELNITSKI-1, Ukraine |
24-03-1992 | INES 2 | UNIT SHUTDOWN DUE TO DEPRESSURIZATION OF ONE FUEL CHANNEL | LENINGRAD-3, Russian Federation |
30-03-1992 | INES 1 | DROPPING OF A SPENT FUEL BUNDLE IN INSPECTION BAY | KALPAKKAM-2, India |
31-03-1992 | INES 0 | REACTOR UNIT NO.2 SCRAM ON TOTAL LOSS OF POWER | TARAPUR-2, India |
10-04-1992 | INES 0 | LOSS OF AC POWER DURING REFUELING WITH UNLOADED REACTOR | BEZNAU-2, Switzerland |
16-04-1992 | INES 1 | DEGRADED WATER CHEMISTRY IN THE PRIMARY CIRCUIT DUE TO CEMENT MORTAR INGRESS INTO THE BORATED WATER STORAGE TANK | KOLA-2, Russian Federation |
19-04-1992 | INES 0 | POWER UNIT UNLOADING DUE TO THE THIRD MAIN CIRCULATION PUMP (MCP-3) TURNING-OFF AS A RESULT OF FALSE OPERATION OF MAJOR PROTECTION SYSTEM | ZAPOROZHE-4, Ukraine |
19-04-1992 | INES 0 | REACTOR UNIT NO.2 SCRAM ON CONSENSER LOW VACUUM | TARAPUR-2, India |
05-05-1992 | INES 0 | MODERATOR DUMP TIME RECORDING HIGHER THAN NORMAL | KALPAKKAM-1, India |
09-05-1992 | INES 1 | REACTOR SHUTDOWN BY TECHNICAL SPECIFICATIONS APPLICATION (UNUSUAL EVENT) | LAGUNA VERDE-1, Mexico |
10-05-1992 | INES 0 | PARTIAL DRAINING OF H2O DOUSING TANK DURING UNIT START UP | RAJASTHAN-2, India |
13-05-1992 | INES 1 | RECIRCULATION TRANSIENT WITH A SUDDEN INCREASE IN POWER OVER 100% | LAGUNA VERDE-1, Mexico |
13-05-1992 | INES 1 | UNIT-2 EMERGENCY CONDENSER LOOP A TUBE FAILURE | TARAPUR-2, India |
15-05-1992 | INES 1 | DEUTERIUM EXCURSION IN MODERATOR COVER GAS | RAJASTHAN-2, India |
28-05-1992 | INES 1 | A NON USUAL EVENT DUE TO THE LIBERATION OF GASES INSIDE THE PLANT | LAGUNA VERDE-1, Mexico |
01-06-1992 | INES 0 | REPAIR OF REACTOR PRESSURE VESSEL HEAD PENETRATION | RINGHALS-2, Sweden |
04-06-1992 | INES 1 | INOPERABILITY OF HERMETIC COMPARTMENT PRESSURE INDICATORS OF ESFAS | DUKOVANY-2, Czech Republic |
10-06-1992 | INES 1 | CONTAMINATED PARTICLES DISCOVERED ON-SITE | KOZLODUY-1, Bulgaria |
15-06-1992 | INES 0 | REACTOR UNIT NO. 1 SCRAM ON TOTAL LOSS OF POWER | TARAPUR-1, India |
19-06-1992 | INES 0 | UNIT NO. 1 SCRAM ON PRM CH. 6 & IRM CH. 9 KICKING UP DURING FUNCTIONAL CHECKS | TARAPUR-1, India |