Laka Foundation

Publication Laka-library:
Analysis of three loss-of-flow accidents in the first wall cooling system of NET/ITER (1993)

AuthorE.Komen, H.Koning
DateMay 1993
Classification6.07.2.23/02 (NUCLEAR FUSION - ITER)
Front

From the publication:

Abstract

This report presents the thermal-hydraulic analysis of three Loss-of-Flow Accidents
(LOFAs) in the first wall cooling system of the Next European Torus (NET) design
or the International Thermonuclear Experimental Reactor (ITER) design.

The LOFAs considered result from a loss of the forced coolant flow caused by
 a loss of electrical power for the recirculation pump in the primary circuit.

The analyses have been performed using the thermal-hydraulic system analysis
code RELAP5/MOD3. In the analyses, special attention has been paid to the
transient thermal-hydraulic behaviour of the cooling system and the temperature
development in the first wall. In the LOFA case without plasma shutdown, melting
starts in the first wall about 150 s after accident initiation. In the LOFA case
with delayed plasma shutdown, melting starts in the first wall when the plasma
shutdown is initiated later than about 110 s after accident initiation. Melting
does not occur in the first wall during a LOFA with prompt plasma scram.

This publication is only available at Laka on paper, not as pdf.
You can borrow the publication or request a copy. When we're available, this is possible for a small fee.