INES 2

HEAVY WATER SPILLAGE IN CONTAINMENT

Wolsong unit 1 was operated at rated power. At 05:11, October 20, 1994 one of the liquid relief valves in the reactor coolant system was opened due to trouble with valve operating mechanism (diaphragm damage). This caused decrease of pressurizer level and resulted in reactor trip by "pressurizer level low" signal. At 06:56 an overpressure protection valve of Degasser-condenser was opened. Reactor coolant system was fully cooled down at 08:10 the same day.
About 6.5 tons of heavy water leaked into heavy water recovery system. No radiation exposure of workers happened.
This event was evaluated as level 1 tentatively. But further investigation revealed that procedures were inadequate to overcome this event.
So the Evaluation Committee of Severity on Incident and Failure determined to apply additional factor. The final rating of this event is 2.
Justification: As full safety functions were available the event is rated at level "0" as per user's manual Part III, Table II, A2 and Part III-5.

Location: WOLSONG-3
Event date: Thu, 20-10-1994