Publicatie Laka-bibliotheek:
Loss-of-Coolant and Loss-of-Flow Accidents in the SEAFP first wall/blanket cooling system (1994)
| Auteur | ECN, Komen, Koning |
| Datum | juli 1994 |
| Classificatie | 6.07.2.29/03 (KERNFUSIE - REST) |
| Voorkant | ![]() |
Uit de publicatie:
Loss-of-coolant and loss-of-flow accidents in the SEAFP first wall/blanket cooling system This paper presents the RELAP5/MOD3 thermal-hydraulic analysis of three Loss-of-Coolant Accidents (LOCAs) and three Loss-of-Flow Accidents (LOFAs) in the first wall/blanket cooling system of the SEAFP reactor design. The analyses deal with the transient thermal-hydraulic behaviour inside the cooling systems and the temperature development inside the nuclear components. As it appears, the temperature increase in the first wall Be-coating is limited to 30 K when an emergency plasma shutdown is initiated within 10 s following pump trip.
Deze publicatie is alleen op papier bij Laka beschikbaar, niet als pdf.
Publicaties zijn te leen of informeer of we een kopie kunnen maken. Soms, als we tijd hebben, lukt dat tegen kostprijs van de kopieën.