Legenda & explanation
date INES title location
21-01-2002INES 2Partial loss of the command and control system in Flamanville NPPFLAMANVILLE-2, France
18-07-1996INES 1Erroneous line-up before start-up of vent pipe valves to the scrubber systemFORSMARK-1, Sweden
25-07-2006INES 2Two emergency dieselgenerators did not start when the unit was disconnected from the ordinary off site grid.FORSMARK-1, Sweden
10-09-1991INES 1REVEAL OF INADVERTENTLY CLOSED MANUAL SERVICE VALVES AT VERIFICATION TESTS OF THE SCRAM SYSTEM BEFORE PREPARATIONS TO RESTARTFORSMARK-2, Sweden
15-07-1995INES 1ONE CLOSED VALVE IN THE CONTAINMENT PRESSURE RELIEF LINE TO THE ATMOSPHERE AND TWO CLOSED VALVES IN THE VENTING LINE TO THE EMERGENCY FILTERFORSMARK-2, Sweden
16-05-1997INES 1Degraded containment pressure suppression function during shutdown of reactor before outage periodFORSMARK-2, Sweden
25-07-2006INES 1INES-rating due to earlier event at Forsmark 1 - Two emergency DG did not start when the unit was disconnected from the ordinary off-site gridFORSMARK-2, Sweden
15-06-1994INES 1UNINTENTIONAL SLOW INSERTION OF ALL CONTROL RODSFORSMARK-3, Sweden
30-05-2013INES 1EDG failed to start after unintentional loss of two phases on 400 kV incoming offsite supplyFORSMARK-3, Sweden
13-06-2012INES 2Irradiation of a worker while handling an Iridium 192 sourceFos-sur-Mer, France
22-11-2012INES 2Potential exposure of airplane passengers to doses in excess of statutory limits for the public due to a damaged type A packageFrankfurt, Germany, Australia
06-11-2016INES 2Transport of package containing a radioactive source from Kenya to South AfricaFrom Kenya to South Africa, South Africa
18-10-1992INES 0UNSCHEDULED SHUTDOWN DUE TO STEAM LEAKAGE FROM AN OUTLET PIPE OF A HIGH PRESSURE TURBINEFUGEN ATR, Japan
12-04-2011INES 7Re-evaluation of INES rating; Effect to the Nuclear Facilities from the earthquake on east area of JapanFukushima Daiichi, Japan
19-08-2013INES 3Contaminated water leakage from a water tankFUKUSHIMA DAIICHI, Japan
22-02-2015Not ApplicablePossible Flow of Contaminated Water to the Outside of the Controlled AreaFUKUSHIMA-DAIICHI, Japan
17-12-2014Not ApplicableLeakage of Water Treated by the Multi-Nuclide Removal Facility (ALPS)FUKUSHIMA-DAIICHI, Japan
17-09-2014Not ApplicableDiscovery of a Crack in a Connection Valve between Tanks for Concentrated Water Treated by Reverse OsmosisFUKUSHIMA-DAIICHI, Japan
02-06-2014Not ApplicableLeakage of Contaminated Water from Two Notch TanksFUKUSHIMA-DAIICHI, Japan
13-04-2014Not ApplicableInappropriate Transfer of Contaminated WaterFUKUSHIMA-DAIICHI, Japan
20-02-2014Not ApplicableLeakega of Contaminated Water from the Upper Part of Tank C-1 in H-6 Tank AreaFUKUSHIMA-DAIICHI, Japan
06-02-2014Not ApplicableLeakage of Contaminated Water from a Flange of Water Pressure Measuring instrumentFUKUSHIMA-DAIICHI, Japan
09-10-2013Not ApplicableLeakage of Contaminated Water from a Desalination SystemFUKUSHIMA-DAIICHI, Japan
02-10-2013Not ApplicableLeakege of Contaminated Water from the Top Plate of a Tank at B Area (South)FUKUSHIMA-DAIICHI, Japan
20-02-2014Not ApplicableLeakage of Contaminated Water from the Upper Part of Tank C-1 in H-6 Tank AreaFUKUSHIMA-DAIICHI, Japan
02-10-2013Not ApplicableLeakage of Contaminated Water from the Top Plate of a Tank at B Area (South)FUKUSHIMA-DAIICHI, Japan
15-09-2015Not ApplicableLeakages of water from the dikes in tank areas storing contaminated waterFUKUSHIMA-DAIICHI, Japan
29-05-2015Not ApplicableContaminated water being transferred to turbine building of unit 3 from 1000 tons notch tank was leaking from the cracked pressure hoseFUKUSHIMA-DAIICHI, Japan
20-04-2016Not ApplicableLeakage from Piping Transferring RO-Concentrated Water to G-6 Tank AreaFUKUSHIMA-DAIICHI, Japan
12-03-2011INES 5Abnormal rise of radioactive dosage value at site boundary (INES Level 4)FUKUSHIMA-DAIICHI-1, Japan