date | INES | title | location |
12-02-1993 | INES 1 | PLUTONIUM RECOVERY PLANT, B204 | BNFL, Sellafield, United Kingdom |
12-02-1993 | INES 2 | OVEREREXPOSURE OF A RADIOGRAPHY INSPECTOR AS A RESULT OF A WOUND | BNFL, Sellafield, United Kingdom |
15-02-1993 | INES 0 | UNIT SHUTDOWN DUE TO HEAVY WATER LEAK AT A FUELLING MACHINE | DARLINGTON-2, Canada |
23-02-1993 | INES 1 | FALL DOWN OF CONNECTOR FRAGMENTS INTO THE REACTOR VESSEL | BOHUNICE-2, Slovakia |
24-02-1993 | INES 1 | CRACKS IN PIPEBENDS (ELBOWS) IN THE RESIDUAL HEAT REMOVAL SYSTEM | OSKARSHAMN-1, Sweden |
25-02-1993 | INES 2 | FEEDWATER PIPE RUPTURE | LOVIISA-2, Finland |
27-02-1993 | INES 1 | WATER INGRESS IN ION CHAMBER HOUSING OF CHANNEL B & E OF REACTOR REGULATING AND PROTECTIVE SYSTEM | NARORA-2, India |
28-02-1993 | INES 0 | MINOR LEAKAGE IN A 32 MM VALVE BONNET SEAL | RINGHALS-1, Sweden |
02-03-1993 | INES 0 | MINOR LEAKAGE IN A 15 MM PIPE TO A PILOT VALVE IN THE PRESSURE RELIEF SYSTEM | RINGHALS-1, Sweden |
03-03-1993 | INES 0 | BLOWN FUSE ON THE INVERTER CAUSED REACTOR TRIP | KRSKO, Slovenia |
05-03-1993 | INES 1 | UNITS DERATED TO 60% REACTOR POWER DUE TO SAFETY ANALYSIS CONCERNS | BRUCE-1, Canada |
05-03-1993 | INES 1 | COOLANT RADIOACTIVITY EXCEEDING OPERATING LIMITS DUE TO FUEL ROD FAILURE | ANGRA-1, Brazil |
14-03-1993 | INES 1 | PVNGS 2 STEAM GENERATOR TUBE RUPTURE | PALO VERDE-2, United States of America |
15-03-1993 | INES 0 | ZION UNIT 2 LOSS OF NSSS CONTROL ROOM ANNUNCIATORS | ZION-2, United States of America |
18-03-1993 | INES 0 | REACTOR SHUTDOWN BY THE ACTUATION EMERGENCY PROTECTION CAUSED BY THE LEVEL RAISE IN DRUM SEPARATOR | CHERNOBYL-3, Ukraine |
26-03-1993 | [N/A] | PERRY UNIT 1 MAIN SERVICE WATER PIPE BREAK | PERRY-1, United States of America |
30-03-1993 | INES 0 | TURBINE TRIP ON SG HIGH-HIGH WATER LEVEL FOLLOWED BY REACTOR TRIP | QINSHAN 1, China |
31-03-1993 | INES 3 | COMPLETE STATION BLACK OUT DUE TO FIRE IN TURBINE BUILDING | NARORA-1, India |
22-04-1993 | INES 1 | INTERVENTION OF AUTOMATIC POWER CONTROL (APC) DUE TO SPURIOUS SIGNAL | BOHUNICE-2, Slovakia |
24-04-1993 | INES 0 | EXCESSIVE FEEDWATER REGULATING VALVE OSCILLATIONS CAUSE WATER HAMMER INDUCED VIBRATION OF THE MAIN FEEDWATER PIPING | NORTH ANNA-2, United States of America |
03-05-1993 | INES 1 | UNCONTROLLED INCREASE OF REACTOR POWER | PAKS-4, Hungary |
10-05-1993 | INES 0 | STEAM GENERATOR TUBE LEAK | KRSKO, Slovenia |
18-05-1993 | INES 2 | SEEPAGE FROM A WASTE DRUM | BNFL, Sellafield, United Kingdom |
21-05-1993 | [N/A] | HYDROGEN IGNITION ON THE COOLING SYSTEM OF THE TURBOGENERATOR | ZAPOROZHE-5, Ukraine |
27-05-1993 | INES 1 | UNIT SCRAM DUE TO INADVERTENT ACTUATION OF PRESSURIZER PILOT RELIEF VALVE | KOLA-3, Russian Federation |
28-05-1993 | [N/A] | EXTRAORDINARY SHUTDOWN OF THE UNIT BECAUSE OF HYDROGEN LEAKAGE IN THE COOLING SYSTEM OF THE GENERATOR | SOUTH UKRAINE-3, Ukraine |
03-06-1993 | INES 1 | DIESEL GENERATOR START FAILURE | BOHUNICE-3, Slovakia |
16-06-1993 | INES 2 | RADIOACTIVE CONTAMINATION OF THE PART OF NPP SITE | ZAPOROZHE-1, Ukraine |
21-06-1993 | INES 2 | OVERFLOW OF A LIQUID EFFLUENT STORAGE TANK | CADARACHE, France |
25-06-1993 | INES 0 | LEVEL DECREASE IN THE EMERGENCY BORON TANK | PAKS-1, Hungary |