25-09-1994 | INES 0 | REACTOR TRIP DUE TO TURBINE TRIP CAUSED BY STEAM GENERATOR LEVEL "HI-HI" SIGNAL | KORI-2, South Korea |
25-02-1995 | INES 0 | SAFETY INJECTION DUE TO PRESSURIZER SPRAY VALVE STACK | KORI-2, South Korea |
27-11-1995 | INES 0 | REACTOR TRIP DUE TO ACTUATION OF MAIN GENERATOR PROTECTION RELAY | KORI-2, South Korea |
18-06-1996 | INES 0 | Reactor trip due to steam generator level low-low signal | KORI-2, South Korea |
18-10-1993 | INES 0 | REACTOR TRIP DUE TO FAST CLOSURE OF MAIN FEED ISOLATION VALVES (MFIV) | KORI-3, South Korea |
03-11-1993 | INES 0 | REACTOR TRIP DUE TO FAST CLOSURE OF MAIN STEAM ISOLATION VALVE (MSIV) | KORI-3, South Korea |
06-12-1993 | INES 0 | REACTOR TRIP DUE TO TURBINE TRIP CAUSED BY STEAM GENERATOR LEVEL "HI-HI" SIGNAL | KORI-3, South Korea |
03-04-1995 | INES 0 | REACTOR TRIP DUE TO MAIN FEEDWATER PUMPS STOP | KORI-3, South Korea |
10-12-1993 | INES 0 | REACTOR TRIP DUE TO FAST CLOSURE OF MAIN FEEDWATER ISOLATION VALVE (MFIV) CAUSED BY MALFUNCTION OF LOGIC CIRCUIT | KORI-4, South Korea |
11-01-1994 | INES 0 | REACTOR TRIP DUE TO FAST CLOSURE OF MAIN STEAM ISOLATION VALVE (MSIV) | KORI-4, South Korea |
29-12-2003 | INES 2 | Unshielded radioactive source found in metal scrap | Meghri, Armenia |
27-12-2008 | INES 0 | Very low activity source found in scrap metal | Meghri, Armenia |
17-11-1992 | INES 2 | OVEREXPOSURE OF WORKER DUE TO THE MALFUNCTION OF THE INTERLOCK SYSTEM | MICROTRON, Viet Nam |
09-02-1991 | INES 2 | STEAM GENERATOR TUBE BREAK | MIHAMA-2, Japan |
08-12-1995 | INES 1 | Secondary sodium leakage in the prototype fast breeder reactor Monju | MONJU, Japan |
31-03-1993 | INES 3 | COMPLETE STATION BLACK OUT DUE TO FIRE IN TURBINE BUILDING | NARORA-1, India |
19-03-1996 | INES 0 | Unit trip on no primary circulating pump running | NARORA-1, India |
28-11-2000 | INES 0 | Forced shutdown of Narora Unit-1 due to unavailability of make up water | NARORA-1, India |
25-04-2003 | INES 1 | Heavy water leak from a defuelled coolant channel in a PHWR during Inspection, with reactor in shutdown state | NARORA-2, India |
27-02-1993 | INES 1 | WATER INGRESS IN ION CHAMBER HOUSING OF CHANNEL B & E OF REACTOR REGULATING AND PROTECTIVE SYSTEM | NARORA-2, India |
27-12-1995 | INES 0 | Reactor trip on low PHT pressure due to change in power while reverse fueling of channel | NARORA-2, India |
05-01-1996 | INES 0 | Reactor trip on adjuster rod cooling flow very low | NARORA-2, India |
11-09-1998 | INES 2 | Overexposure of two workers | NARORA-2, India |
15-04-2000 | INES 1 | Moderator water leak in moderator room | NARORA-2, India |
28-08-2009 | INES 2 | Contamination of a vehicle with Cs-137 | NO facility associated to this event, Armenia |
07-04-2008 | INES 1 | Loss of Industrial Gamma Radiography Exposure Device containing Ir-192 radiography source | Non-Destructive Inspection Co., Ltd / Chiba, Japan |
17-11-2002 | [N/A] | Chemical Explosion at fuel fabrication facility | Nuclear Fuel Complex, Hyderabad, India |
06-06-2017 | INES 2 | Exposure of Workers at Plutonium Fuel Research Facility | Oarai Research and Development Center, Japan |
11-12-1994 | INES 1 | REACTOR AUTOMATIC SHUTDOWN BY SIGNAL OF NUCLEAR INSTRUMENTATION SYSTEMSYSTEM | ONAGAWA-1, Japan |
11-03-2011 | INES 2 | Failure of the reactor component cooling water system and others by tsunami | ONAGAWA-2, Japan |