date  | INES | title | location |
| 11-08-1996 | INES 0 | Manual shutdown for repairing of main condenser tube | ULCHIN-1, South Korea |
| 07-08-1996 | INES 0 | Manual shutdown for repairing the steam generator tube leak | YONGGWANG-2, South Korea |
| 05-08-1996 | INES 1 | Release of iodine-131 from 131 production plant of nuclear chemistry division Pakistan Institute of Nuclear Science and Technology | PINSTEC, Pakistan |
| 24-07-1996 | INES 2 | Over-exposure of one worker during the industrial radiography activities | GILAN, Iran |
| 12-07-1996 | INES 0 | Manual shutdown for repairing the fueling machine | WOLSONG-3, South Korea |
| 10-07-1996 | INES 0 | Reactor trip due to the malfunction of optical isolator | YONGGWANG-4, South Korea |
| 19-06-1996 | INES 0 | Reactor trip due to the malfunction of optical isolator | YONGGWANG-4, South Korea |
| 18-06-1996 | INES 0 | Reactor trip due to steam generator level low-low signal | KORI-2, South Korea |
| 16-06-1996 | INES 0 | Fire incident in boiler room | KANUPP, Pakistan |
| 15-05-1996 | INES 0 | Reactor trip due to steam generator level low signal | YONGGWANG-4, South Korea |
| 25-04-1996 | INES 0 | Reacotr trip due to steam generator level high signal | ULCHIN-1, South Korea |
| 31-03-1996 | INES 0 | Reactor trip due to improper operation of main feedwater bypass valve | KORI 1, South Korea |
| 30-03-1996 | INES 0 | Reactor trip due to actuation of sensitive relay influenced by starting current | KORI 1, South Korea |
| 29-03-1996 | INES 0 | Power excursion and subsequent plant trip | KANUPP, Pakistan |
| 19-03-1996 | INES 0 | Unit trip on no primary circulating pump running | NARORA-1, India |
| 13-02-1996 | INES 0 | REACTOR COOLANT SPILLAGE DURING OVERHAUL | YONGGWANG-3, South Korea |
| 02-02-1996 | INES 0 | Reactor trip due to degradation of photoresistic cell in the main feedwater control system | ULCHIN-1, South Korea |
| 23-01-1996 | INES 0 | Reactor trip due to spurious signal generated by mistake of worker | YONGGWANG-1, South Korea |
| 22-01-1996 | INES 0 | LEAKAGE OF THE FEEDWATER OF RECIRCULATION PIPELINE | BN-350, Kazakhstan |
| 17-01-1996 | INES 0 | WRONG SWITCH-OFF OF THE OIL-SYSTEM OPERATING SECONDARY COOLANT PUMP | BN-350, Kazakhstan |
| 07-01-1996 | INES 0 | D2O leak from a calandria tube sheet plug | KALPAKKAM-1, India |
| 05-01-1996 | INES 3 | A worker was injured by an overexposure of Iridium-192 lost source from a gamma radiograph | JIHUA, China |
| 05-01-1996 | INES 0 | Reactor trip on adjuster rod cooling flow very low | NARORA-2, India |
| 27-12-1995 | INES 0 | Reactor trip on low PHT pressure due to change in power while reverse fueling of channel | NARORA-2, India |
| 15-12-1995 | INES 0 | TURBINE TRIP AND REACTOR SCRAM DUE TO TO AG WATER LEVEL HIGH-HIGH | QINSHAN 1, China |
| 08-12-1995 | INES 1 | Secondary sodium leakage in the prototype fast breeder reactor Monju | MONJU, Japan |
| 27-11-1995 | INES 0 | REACTOR TRIP DUE TO ACTUATION OF MAIN GENERATOR PROTECTION RELAY | KORI-2, South Korea |
| 21-11-1995 | INES 3 | Two occupational workers were injured by exposure of electron accelerator | TIANJIN, China |
| 10-11-1995 | INES 1 | Non-closure of primary steam isolating valves on auto during total loss of power incident | TARAPUR-1, India |
| 24-09-1995 | INES 0 | MANUAL REACTOR TRIP DUE TO FAILURE OF DRAIN VALVE IN AUTOCLAVE CIRCUIT | WOLSONG-3, South Korea |