INES-events in ADDER
INES type: power-reactor
▸
▾
Legenda & explanation
This map shows a selection of reports from nuclear and radiological incidents stored in the IAEA NEWS-database.
Locations are estimates.
Contact us
if a location is wrong.
The map shows a maximum of 100 incidents. If hundred incidents or more are within the map, the yellow perimeter indicates from where events are excluded. Drag or zoom the map to explore different areas.
Power Reactor
Research Reactor
Radwaste Facility
Enrichment Facility
Radiation Source
Irradiation/Accelerator Facility
Transportation
Fuel Fabrication
Fuel Reprocessing
Research Facility
Mining/Milling
Radioisotope Processing/Handling Facility
Other
date
INES
title
location
1994-08-09
INES 0
AUTOMATIC REACTOR SHUTDOWN CAUSED BY GENERATOR TRIP
Lithuania
IGNALINA-1
1994-11-03
INES 0
INFRINGEMENT OF THE REACTOR PRIMARY CIRCUIT INTEGRITY
Lithuania
IGNALINA-1
1995-11-12
INES 0
AUTOMATIC REACTOR UNLOADING DUE TO TURBOGENERATOR TRIP BY OPERATOR
Lithuania
IGNALINA-1
1996-02-09
INES 0
REACTOR SHUTDOWN BY THE FAST-ACTING SCRAM SYSTEM DUE TO SPURIOUS SIGNALS OF INCREASED PRESSURE IN THE ISOLATION CONTROL VALVES ROOM
Lithuania
IGNALINA-1
1998-03-03
INES 0
Reactor trip resulting from fast acting scram system (FASS) actuation
Lithuania
IGNALINA-1
1991-05-04
INES 3
PERSONNEL OVEREXPOSURE DURING PRECOMMISSIONING OPERATIONS INVOLVING HOT CELL
Lithuania
IGNALINA-2
1992-10-15
INES 0
LEAKAGE FROM REACTOR CIRCUIT PIPE, DIAMETER 26
Lithuania
IGNALINA-2
1992-10-15
INES 1
LEAKAGE OF REACTOR CIRCUIT PIPE 76 MM DIAMETER FROM REACTOR CHANNEL 32-24 TO THE DRUM SEPARATOR
Lithuania
IGNALINA-2
1994-01-27
INES 0
MANUAL REACTOR SHUTDOWN CAUSED BY THE FAILURE OF THE MANUAL REACTOR CONTROL ROD SYSTEM
Lithuania
IGNALINA-2
1994-02-24
INES 1
DETERIORATION OF THE PRIMARY CIRCUIT INTEGRITY
Lithuania
IGNALINA-2
1994-07-08
INES 0
AUTOMATIC REACTOR SHUTDOWN CAUSED BY SPURIOUS CLOSING OF THE GATE VALVE AT THE PIPELINE FEEDING THE MAIN CONDENSATE HEATER WITH HEATING STEAM
Lithuania
IGNALINA-2
1994-07-11
INES 1
MALFUNCTION IN THE SYSTEM OF NEUTRON CONTROL OF REACTOR POWER FOLLOWING THE REPLACEMENT OF A CONTROL ROD SWITCH
Lithuania
IGNALINA-2
1995-11-22
INES 1
AUTOMATIC REACTOR UNLOADING DUE TO SPURIOUS OPENINGS OF VALVES BETWEEN A GROUP OF ECCS PRESSURIZED TANKS AND REACTOR
Lithuania
IGNALINA-2
1995-11-30
INES 1
OVEREXPOSURE OF OPERATOR DURING CALIBRATION OF IN-CORE SENSORS
Lithuania
IGNALINA-2
1996-01-07
INES 0
MANUAL REACTOR SHUTDOWN DUE TO LEAKAGE IN BLEED WATER RETURN PIPELINE
Lithuania
IGNALINA-2
2002-07-12
INES 2
Engineering Safety Feature Inoperative at Laguna Verde NPP-1
Mexico
LAGUNA VERDE-1
1992-05-09
INES 1
REACTOR SHUTDOWN BY TECHNICAL SPECIFICATIONS APPLICATION (UNUSUAL EVENT)
Mexico
LAGUNA VERDE-1
1992-01-18
INES 1
AN IMPORTANT LOSS OF COMMUNICATIONS IN MAIN CONTROL ROOM
Mexico
LAGUNA VERDE-1
1992-05-13
INES 1
RECIRCULATION TRANSIENT WITH A SUDDEN INCREASE IN POWER OVER 100%
Mexico
LAGUNA VERDE-1
1992-05-28
INES 1
A NON USUAL EVENT DUE TO THE LIBERATION OF GASES INSIDE THE PLANT
Mexico
LAGUNA VERDE-1
1992-09-18
INES 1
LOSS OF INTERNAL POWER DUE TO THE TRIP OF THE MAIN TRANSFORMER (T-1)
Mexico
LAGUNA VERDE-1
1998-11-21
INES 2
Fuel assembly drop during refuelling
Mexico
LAGUNA VERDE-1
2011-01-15
INES 0
Reactor trip due to failure in the Main Generator
Mexico
LAGUNA VERDE-1
2010-12-02
INES 1
Non Usual Event declared due to loss of outside power at Laguna Verde NPP U1
Mexico
LAGUNA VERDE-1
2019-11-16
INES 2
Potential uncontrolled access to room with radiation greater than 1000 mR / hr
Mexico
LAGUNA VERDE-1
Bladeren
« previous
1
...
8
9
10
11
12
13
14
15
16
17
18
19
...
26