06-03-2023INES 2Stress corrosion: presence of a deep crack on the safety injection system of reactor 1 of the Penly NPPPENLY-1, France
21-07-2022INES 2Contamination of an employee and the break room in a nuclear medicine departmentSCINTIGARD radiology centre (Nîmes), France
24-09-2023INES 2Worker Exceeded Statuary Annual Whole Body Dose LimitsMachine Factory, Baden-Württemberg, Germany
26-09-2023INES 2Worker Exceeded Annual Whole Body Dose LimitOdessa, TX / Pro Inspection Inc., United States of America
31-12-2019INES 2Radon Exposure at Boarding SchoolKingswood School, Bath, United Kingdom
22-02-2024INES 2Worker Exceeded Annual Extremity Dose LimitAlton, IL / Alton Steel, United States of America
15-11-2023INES 2Partial loss of post-trip coolingTORNESS-2, United Kingdom
11-12-2023INES 2Worker Exceeded Annual Dose LimitRomeoville, Illinois/ SOFIE, United States of America
11-01-2024INES 2Unavailability of Reactor protection system of unit 3DUKOVANY-3, Czech Republic
15-12-2022INES 2Worker OverexposureGilroy, California/ SOFIE, United States of America
12-09-2023INES 2Accidential Exposure of Industrial Radiography WorkerYeosu, South Korea
24-08-2018INES 2Accidential Exposure of Industrial Radiography WorkerGeoje, South Korea
20-04-2015INES 2Accidential Exposure of Industrial Radiography WorkerBusan, South Korea
27-02-2025INES 2Stolen Radiography CameraKernersville, North Carolina / IQS Inspections, United States of America
08-04-2025INES 2Workers Exceeded Annual Dose LimitNoblesville, Indiana/ Curium US LLC, United States of America
09-06-2025INES 2External contamination of a worker beyond the annual statutory limit to the skinCATTENOM-3, France
13-01-2025INES 2Radiation worker exposureNuclear Physics Institute, Praha, Czech Republic
19-08-2025INES 2Worker Exceeded Annual Whole Body Dose LimitBavaria / Company for Material Testing, Germany
11-04-2001INES 1Shut down of Rovno NPP unit 2 because of fall of a crane's boomROVNO-2, Ukraine
04-04-2001INES 1Discovery of an Interlock Defeat applied to the Fuelling Machine d/P/dT Protection system without applicationDUNGENESS-B1 UNIT A, United Kingdom
20-06-2001INES 1Incorrect calculation of an algorithm in overload protection devices for local power distribution at Ringhals 2 NPP.RINGHALS-2, Sweden
19-07-2001INES 1Underdimensioned rupture disc installed in the FILTRA-systemBARSEBECK-2, Sweden
30-06-2001INES 1Unauthorized dismantling of a furnace containing Co-60 radioactive sourcesS.C. Forever/ Calan, Romania
29-11-2001INES 1Loss of radioactive source Cs-137 included in a Beckman deviceCERNAVODA-1, Romania
18-01-2002INES 1Radioactice source found in a scrap recycling facility in GreeceHalivourgiki / Aspropirgos, Greece
21-01-2002INES 1THEFT OF NUCLEAR GAUGE WITH CS-137 AND AM-BE SOURCESLima, Peru
14-12-2001INES 1DESTRUCTION OF A PIPING INSIDE CONTAINMENTBRUNSBUETTEL, Germany
16-02-2002INES 1Site contamination at Khmelnitsky NPPKHMELNITSKI-1, Ukraine
09-04-2002INES 1Damage of a type "A" package during transhipment at Roissy airport (France) between Poland and UkraineRoissy Charles De Gaulle airport, France
05-07-2002INES 1Unshielded Radioactive Source Eu-152 in Metal scrapUzimet BV, Rijswijk ZH, Netherlands