Europe: Ukraine

Legenda & explanation
date INES title location
12-11-1992INES 1UNIT OPERATION WITH ONE REACTOR PROTECTION SYSTEM CHANNEL OUTSOUTH UKRAINE-2
21-09-1992INES 2REACTOR SHUTDOWN CAUSED BY AN EMERGENCY PROTECTION SYSTEM ACTUATION FOLLOWED BY NON-COMPLIANCE WITH THE SAFETY LIMITSSOUTH UKRAINE-1
19-04-1992INES 0POWER UNIT UNLOADING DUE TO THE THIRD MAIN CIRCULATION PUMP (MCP-3) TURNING-OFF AS A RESULT OF FALSE OPERATION OF MAJOR PROTECTION SYSTEMZAPOROZHE-4
18-03-1992[N/A]NO IMPACT TO SAFETY FOLLOWING RUPTURE OF A BYPASS FEEDWATER LINEKHMELNITSKI-1
30-12-1991INES 2UNIT SHUTDOWN AS A RESULT OF SPURIOUS OPERATION OF THE FIRE EXTINGUISHING SYSTEM AND DUE TO FLOODING OF ESFAS PANELSZAPOROZHE-2
02-10-1991INES 2CONTAMINATION OF THE SECONDARY WATER DUE TO ERRORS OF THE SPECIAL WATER TREATMENT FACILITY PERSONNELZAPOROZHE-2
01-07-1991INES 2NEW FUEL ASSEMBLY DROPPING WHILE REFUELINGCHERNOBYL-2
23-01-1991INES 2UNIT SHUTDOWN DUE TO BREACH OF NORMAL OPERATION CONDITIONSZAPOROZHE-1
01-12-1990INES 2ESSENTIAL BUS DEENERGIZATIONSOUTH UKRAINE-1
01-11-1991INES 0PARTIAL DAMAGE TO POWER AND INSTRUMENTATION CABLES OF TURBINE BUILDING VALVES AND AUXILIARY COMPONENTS AS A RESULT OF IGNITIONCHERNOBYL-1
11-10-1991INES 2UNIT SHUTDOWN DUE TO FIRE IN THE TURBINE BUILDING CAUSED BY ELECTRICAL EQUIPMENT FAILURECHERNOBYL-2
10-08-1991INES 2PRIMARY WATER SPILLAGE WHILE REPAIR OF THE GATE VALVE AT RCP SUCTION DURING SCHEDULED MAINTENANCECHERNOBYL-2
10-04-1991INES 3UNAVAILABILITY OF LOW POWER EMERGENCY PROTECTION (LPEP) DUE TO LOSS OF IONIZATION CHAMBER POWER SUPPLYCHERNOBYL-1
26-02-1991INES 3INOPERABILITY OF VALVES AT THE DISCHARGE SIDE OF HPSI PUMPS IN THREE TRAINS DUE TO FAILURE TO CONNECT POWER CABLESKHMELNITSKI-1
27-03-1991INES 0UNIT SHUTDOWN DUE TO PRIMARY CIRCUIT LEAK IN THE LINE OF CONTROLLED LEAKS FROM THE MAIN ISOLATION VALVE SEALSOUTH UKRAINE-1
13-02-1991INES 0REACTOR SHUTDOWN DUE TO EXCESS HYDROGEN CONCENTRATION IN THE GENERATOR STATOR GAS TRAPZAPOROZHE-4
16-02-2002INES 1Site contamination at Khmelnitsky NPPKHMELNITSKI-1
11-04-2001INES 1Shut down of Rovno NPP unit 2 because of fall of a crane's boomROVNO-2