| date | INES | title | location |
| 12-10-1993 | INES 1 | IMPENETRABILITY TEST OF CONTAINMENT NOT APPROVED | BARSEBECK-2, Sweden |
| 12-01-1994 | INES 2 | RADIOACTIVE CONTAMINATION IN AUXILIARY BUILDING | ZAPOROZHE-4, Ukraine |
| 27-12-1993 | INES 2 | RADIATION EXPOSURE OF WORKERS AT TOKAI REPROCESSING PLANT | TOKAI REPROCESSING PLANT, Japan |
| 23-11-1993 | INES 0 | UNIT SCRAM DUE TO OPERATIONAL OCCURRENCE IN RCP COMPONENT COOLING CIRCUIT | KALININ-1, Russian Federation |
| 26-11-1993 | INES 1 | HUMAN ERROR INITIATED SAFETY INJECTION/REACTOR TRIP | KRSKO, Slovenia |
| 13-11-1993 | INES 2 | UNCONTROLLED POWER TRANSIENT IN A TEST REACTOR WITH DEGRADATION OF THE TESTED IRRADIATED FUEL NEEDLE | BR2, Belgium |
| 20-10-1993 | [N/A] | DISAPPEARANCE OF TWO FUEL ELEMENTS FROM THE FRESH FUEL STORAGE PREMISES | CHERNOBYL-3, Ukraine |
| 14-09-1993 | INES 0 | LOSS OF OFF-SITE POWER AND REACTOR SCRAM | LASALLE-1, United States of America |
| 16-09-1993 | INES 0 | REACTOR TRIP DUE TO STEAM GENERATOR HIGH HIGH LEVEL SIGNAL | YONGGWANG-2, South Korea |
| 10-08-1993 | INES 0 | REACTOR TRIP DUE TO STEAM GENERATOR HIGH HIGH LEVEL SIGNAL | YONGGWANG-2, South Korea |
| 09-08-1993 | INES 0 | REACTOR SHUTDOWN DUE TO LIGHTNING | YONGGWANG-2, South Korea |
| 02-07-1993 | INES 0 | REACTOR TRIP DUE TO STEAM GENERATOR LOW LOW LEVEL SIGNAL | KORI 1, South Korea |
| 07-10-1993 | INES 1 | RADIOACTIVE CONTAMINATION OF THE UNIT ROOMS DUE TO REACTOR COOLANT LEAK IN THE AUXILIARY SYSTEM | BELOYARSKY-3(BN-600), Russian Federation |
| 16-08-1993 | [N/A] | MINOR FIRE INVOLVING A SAFETY RELATED SYSTEM | H.B. ROBINSON-2, United States of America |
| 20-01-1993 | INES 2 | SUB-COOLING OF THE REACTOR COOLANT SYSTEM DURING A TEST | PALUEL-2, France |
| 31-07-1993 | INES 2 | REFUELLING GRAB FAILURE AT WYLFA | WYLFA UNIT A, United Kingdom |
| 02-08-1993 | [N/A] | FIRE ON THE CENTRAL PUMP STATION ROOF | DUKOVANY-1, Czech Republic |
| 27-02-1993 | INES 1 | WATER INGRESS IN ION CHAMBER HOUSING OF CHANNEL B & E OF REACTOR REGULATING AND PROTECTIVE SYSTEM | NARORA-2, India |
| 16-01-1993 | INES 0 | NON TRIPPING OV CHANNEL-E ON HIGH BOILER DIFFERENTIAL TEMPERATURE WHILE DOING TESTING | KALPAKKAM-2, India |
| 17-01-1993 | INES 0 | NON-AVAILABILITY OF CHANNEL TEMPERATURE MONITORING (CTM) INSTALLATION-2 | RAJASTHAN-2, India |
| 29-06-1993 | INES 2 | INTAKE OF RADIOACTIVE MATERIAL BY OPERATORS AT DOUNREAY | DOUNREAY, United Kingdom |
| 02-02-1993 | INES 1 | UNIT SCRAM CAUSED BY GRID DISTURBANCES DUE TO TORNADO | KOLA-4, Russian Federation |
| 02-02-1993 | INES 1 | UNIT SCRAM CAUSED BY GRID DISTURBANCES DUE TO TORNADO | KOLA-3, Russian Federation |
| 05-07-1993 | INES 0 | FIRE AT COOLING TOWERS | INR-PITESTI, Romania |
| 28-06-1993 | INES 0 | RADIOACTIVE SPOT AT THE NPP SITE | ZAPOROZHE-1, Ukraine |
| 21-06-1993 | INES 2 | OVERFLOW OF A LIQUID EFFLUENT STORAGE TANK | CADARACHE, France |
| 02-02-1993 | INES 3 | UNIT SCRAM CAUSED BY GRID DISTURBANCES DUE TO TORNADO | KOLA-2, Russian Federation |
| 27-05-1993 | INES 1 | UNIT SCRAM DUE TO INADVERTENT ACTUATION OF PRESSURIZER PILOT RELIEF VALVE | KOLA-3, Russian Federation |
| 16-06-1993 | INES 2 | RADIOACTIVE CONTAMINATION OF THE PART OF NPP SITE | ZAPOROZHE-1, Ukraine |
| 28-05-1993 | [N/A] | EXTRAORDINARY SHUTDOWN OF THE UNIT BECAUSE OF HYDROGEN LEAKAGE IN THE COOLING SYSTEM OF THE GENERATOR | SOUTH UKRAINE-3, Ukraine |