Europe

Legenda & explanation
date INES title location
02-05-2013INES 2Overexposure of 4 persons exceeding the statutory annual whole body dose limit for workers (20 mSv)Nuclear Engineering Seiberdorf, Univ. Innsbruck, Austria
20-05-1997[N/A]Small fire in the research reactor LR-O building in RezNUCLEAR RESEARCH INST., Czech Republic
10-07-2001INES 2Contamination of workers during dismantling of alpha dry glove boxesNUCLEAR RESEARCH INST., REZ, Czech Republic
20-07-2021INES 2Overexposure of two workersOCA ICP, Madrid, Spain
17-07-2014INES 2Overexposure to workers to radiografic sourceOceaneering Asset Integrity, Norway
30-05-2008INES 1Fast stop of the main circulation pumps and simultaneous loss of their fly wheel systems during reactor scram.OLKILUOTO-1, Finland
12-04-1991INES 2FIRE IN SWITCHGEAR BUILDINGOLKILUOTO-2, Finland
10-12-2020INES 0Nuclear Installation Event at OLKILUOTO-2OLKILUOTO-2, Finland
25-11-2005INES 1I-192 sealed source stolenORAT s.r.l. Company for industrial non destructive analysis, Italy
01-10-1990INES 1FAULTY WELD DETECTED ON PRIMARY CIRCUITOSKARSHAMN-1, Sweden
24-02-1993INES 1CRACKS IN PIPEBENDS (ELBOWS) IN THE RESIDUAL HEAT REMOVAL SYSTEMOSKARSHAMN-1, Sweden
31-03-1995INES 0CRACKS IN PUMP AND VALVE CASINGSOSKARSHAMN-1, Sweden
01-01-1995INES 0CRACKS IN THE REACTOR CORE SHROUD IN THE LID OF THE SHROUD AND IN REACTOR VESSEL INTERNALSOSKARSHAMN-1, Sweden
01-01-1995INES 1DESIGN DEFICIENCIES IDENTIFIED IN SEPARATION OF ELECTRICAL SYSTEM, AVOIDANCE OF COMMON CAUSE FAILURES IN THE REACTOR PROTECTION SYSTEM AND OVERPRESSURE RELEASE IN THE AUX BUILD.OSKARSHAMN-1, Sweden
26-08-1995INES 1DESIGN DEFICIENCIES IN DIESEL GENERATORS FOUND DURING EXTENDED TESTINGOSKARSHAMN-1, Sweden
21-01-1996INES 1A PART OF THE RESIDUAL HEAT REMOVAL SYSTEM - THE AUXILIARY CONDENSER - TEMPORARILY NOT AVAILABLEOSKARSHAMN-1, Sweden
04-03-1996INES 1FAILURE OF A CONTAINMENT ISOLATION VALVE AT A PERIODICAL TESTOSKARSHAMN-1, Sweden
14-08-1991INES 1DEVIATION FROM OPERATING INSTRUCTIONSOSKARSHAMN-2, Sweden
01-11-1996INES 2One of the emergency core cooling systems - the core spray system - was unavailable at Oskarshamn-2OSKARSHAMN-2, Sweden
25-02-1999INES 0Core instability occurred during maintenance performed in the switchyardOSKARSHAMN-2, Sweden
21-05-2008[N/A]Small traces of explosives found in a security checkpoint near a NPPOSKARSHAMN-2, Sweden
20-11-1987INES 2CRITICALITY SHUT DOWN MARGIN MEASUREMENT STARTED WITHOUT HYDRAULIC SCRAM SYSTEM BEING OPERABLEOSKARSHAMN-3, Sweden
14-03-2008INES 1Stainless steel coils contaminated by Cobalt 60Other, Italy
23-02-2012INES 1Am-241 source meltingOutokumpu Tornio Works, Finland
11-02-2021INES 1Violation of OL&C in the Interim Spent Fuel Storage Facility at PaksPaks, Hungary
29-05-2022INES 1Violation of Operational Limits and Conditions is the Interim Spent Fuel Storage FacilityPaks, Interim Spent Fuel Storage Facility, Hungary
18-07-1991INES 1REACTOR SCRAM AND COOLDOWN BECAUSE OF LEAKAGE IN A PRIMARY CIRCUIT MEASURING SYSTEMPAKS-1, Hungary
25-06-1993INES 0LEVEL DECREASE IN THE EMERGENCY BORON TANKPAKS-1, Hungary
07-07-2008INES 1Deterioration of the containment depression of unit 1 during an air locking operation for maintenance activitiesPAKS-1, Hungary
05-09-2012INES 1Inadequate planned repair of the 10UV68S201 quick-acting gate valve despite of the regulations of the Operational Limits and ConditionsPAKS-1, Hungary