date | INES | title | location |
01-05-1995 | INES 2 | ELEVATED URANIUM LUNG BURDEN | BNFL SPRINGFIELDS |
09-06-1997 | INES 0 | Fire involving used extract ventilation filters | BNFL SPRINGFIELDS |
08-09-1992 | INES 3 | PLUTONIUM NITRATE LEAK IN CELL | BNFL, Sellafield |
12-01-1993 | INES 2 | SIGNIFICANT SPILLAGE OF PLUTONIUM LADEN SOLVENT | BNFL, Sellafield |
12-02-1993 | INES 1 | PLUTONIUM RECOVERY PLANT, B204 | BNFL, Sellafield |
12-02-1993 | INES 2 | OVEREREXPOSURE OF A RADIOGRAPHY INSPECTOR AS A RESULT OF A WOUND | BNFL, Sellafield |
18-05-1993 | INES 2 | SEEPAGE FROM A WASTE DRUM | BNFL, Sellafield |
18-10-1993 | INES 0 | ACID SPILLAGE IN THORP | BNFL, Sellafield |
04-07-1995 | INES 2 | SKIN EXPOSURE IN EXCESS OF DOSE LIMIT | BNFL, Sellafield |
24-03-1995 | INES 2 | CONFIRMED DOSE ABOVE STATUTORY DOSE LIMIT PROBABLY DUE TO A WOUND | BNFL, Sellafield |
03-02-1997 | INES 2 | Spillage of active liquor | BNFL, Sellafield |
02-02-1997 | INES 2 | Release of airborne activity into the workplace resulted in a building evacuation | BNFL, Sellafield |
11-04-1999 | INES 2 | Spillage of radioactive materials | BNFL, Sellafield |
18-10-1999 | INES 2 | Incorrectly packaged radioactive sources | BNFL, Sellafield |
20-04-2005 | INES 3 | Fractured Pipe in Thorp Reprocessing plant | BNFL, Sellafield |
15-06-1991 | INES 2 | TEMPERATURE TRANSIENT DURING START-UP | BRADWELL UNIT A |
29-06-1993 | INES 2 | INTAKE OF RADIOACTIVE MATERIAL BY OPERATORS AT DOUNREAY | DOUNREAY |
07-05-1998 | INES 2 | Loss of ventilation in Dounreay fuel cycle area | DOUNREAY |
31-12-2018 | INES 2 | External corrosion affecting multiple systems on a power reactor | DUNGENESS B |
04-04-2001 | INES 1 | Discovery of an Interlock Defeat applied to the Fuelling Machine d/P/dT Protection system without application | DUNGENESS-B1 UNIT A |
11-07-2003 | INES 2 | Auto-trip of R21, following trip of Main Boiler Feed Pump, subsequent breach of Gas Circulator 22 Inlet Temp. limit | DUNGENESS-B1 UNIT A |
29-06-2009 | INES 2 | Introduction of potentially moderating material to fuel route | DUNGENESS-B1 UNIT A |
19-11-1999 | INES 2 | Discovery of a crack in boiler superheater penetration | DUNGENESS-B2 UNIT B |
15-11-2019 | INES 2 | Radioisotope Manufacture Facility – Operator’s hands contaminated | England, F-18 Cyclotron Facility |
24-09-2018 | INES 2 | Misdelivered Radioactive Transport Packages | Export packing company in vicinity of Heathrow |
22-07-2021 | INES 2 | Automatic trip of both reactors following loss of off-site electric supplies | Heysham 1 Power Station |
22-07-2021 | INES 2 | Automatic trip of both reactors following loss of off-site electric supplies | Heysham 1 Power Station |
11-03-2002 | INES 2 | Consequential failure of Fuelling Machine Interlock at Buffer Storage Tube | HEYSHAM-1 UNIT A |
09-05-1991 | INES 2 | ISOLATION OF FUEL OIL TO ESSENTIAL GAS TURBINES | HINKLEY POINT-B UNIT A |
27-12-1998 | INES 2 | Loss of off-site power supplies at Hunterston B Power Station | HUNTERSTON-B1 UNIT A |