date  | INES | title | location |
| 29-03-1996 | INES 0 | Power excursion and subsequent plant trip | KANUPP, Pakistan |
| 19-03-1996 | INES 0 | Unit trip on no primary circulating pump running | NARORA-1, India |
| 04-03-1996 | INES 1 | FAILURE OF A CONTAINMENT ISOLATION VALVE AT A PERIODICAL TEST | OSKARSHAMN-1, Sweden |
| 28-02-1996 | INES 1 | Internal Contamination of Several Workers While Cleaning up Equipment | VANDELLOS-1, Spain |
| 13-02-1996 | INES 0 | REACTOR COOLANT SPILLAGE DURING OVERHAUL | YONGGWANG-3, South Korea |
| 09-02-1996 | INES 0 | REACTOR SHUTDOWN BY THE FAST-ACTING SCRAM SYSTEM DUE TO SPURIOUS SIGNALS OF INCREASED PRESSURE IN THE ISOLATION CONTROL VALVES ROOM | IGNALINA-1, Lithuania |
| 06-02-1996 | INES 1 | LOSS OF OFFSITE POWER AND SAFETY INJECTION | CATAWBA-2, United States of America |
| 02-02-1996 | INES 0 | Reactor trip due to degradation of photoresistic cell in the main feedwater control system | ULCHIN-1, South Korea |
| 31-01-1996 | INES 1 | Reactor scram followed by the actuation of safety valve in the reactor primary circuit | NIIAR Inst., Dimitrovgrad, Russian Federation |
| 30-01-1996 | INES 2 | PARTIAL LOSS OF ESSENTIAL SERVICE WATER DUE TO FRAZIL ICE ON INTAKE TRASH RACKS | WOLF CREEK, United States of America |
| 23-01-1996 | INES 0 | Reactor trip due to spurious signal generated by mistake of worker | YONGGWANG-1, South Korea |
| 22-01-1996 | INES 0 | LEAKAGE OF THE FEEDWATER OF RECIRCULATION PIPELINE | BN-350, Kazakhstan |
| 21-01-1996 | INES 1 | A PART OF THE RESIDUAL HEAT REMOVAL SYSTEM - THE AUXILIARY CONDENSER - TEMPORARILY NOT AVAILABLE | OSKARSHAMN-1, Sweden |
| 17-01-1996 | INES 0 | WRONG SWITCH-OFF OF THE OIL-SYSTEM OPERATING SECONDARY COOLANT PUMP | BN-350, Kazakhstan |
| 08-01-1996 | INES 0 | SUDDEN OPENING OF SAFETY STEAM VALVES DURING A ROUTINE TEST OF THE ECCS CONTROL LOGIC, WITHOUT ANY SAFETY-RELATED CONSEQUENCES | EMBALSE, Argentina |
| 07-01-1996 | INES 0 | MANUAL REACTOR SHUTDOWN DUE TO LEAKAGE IN BLEED WATER RETURN PIPELINE | IGNALINA-2, Lithuania |
| 07-01-1996 | INES 0 | D2O leak from a calandria tube sheet plug | KALPAKKAM-1, India |
| 05-01-1996 | INES 3 | A worker was injured by an overexposure of Iridium-192 lost source from a gamma radiograph | JIHUA, China |
| 05-01-1996 | INES 0 | Reactor trip on adjuster rod cooling flow very low | NARORA-2, India |
| 27-12-1995 | INES 0 | Reactor trip on low PHT pressure due to change in power while reverse fueling of channel | NARORA-2, India |
| 18-12-1995 | INES 2 | PRESSURE TUBE FAILURE AND SMALL LOCA IN EMBALSE NPP AFTER GARTER SPRING INSPECTION AND RELOCATION | EMBALSE, Argentina |
| 15-12-1995 | INES 0 | TURBINE TRIP AND REACTOR SCRAM DUE TO TO AG WATER LEVEL HIGH-HIGH | QINSHAN 1, China |
| 13-12-1995 | INES 0 | SMALL RADIOACTIVITY RELEASE | KRSKO, Slovenia |
| 08-12-1995 | INES 1 | Secondary sodium leakage in the prototype fast breeder reactor Monju | MONJU, Japan |
| 03-12-1995 | INES 0 | UNIT COLD SHUT DOWN BECAUSE OF THE FLAW IN PIPELINE OF THE PRIMARY MAIN COOLANT PUMP | ZAPOROZHE-1, Ukraine |
| 30-11-1995 | INES 1 | OVEREXPOSURE OF OPERATOR DURING CALIBRATION OF IN-CORE SENSORS | IGNALINA-2, Lithuania |
| 27-11-1995 | INES 0 | REACTOR TRIP DUE TO ACTUATION OF MAIN GENERATOR PROTECTION RELAY | KORI-2, South Korea |
| 27-11-1995 | INES 3 | RADIOACTIVE CONTAMINATION IN THE REACTOR BUILDING | CHERNOBYL-1, Ukraine |
| 22-11-1995 | INES 1 | AUTOMATIC REACTOR UNLOADING DUE TO SPURIOUS OPENINGS OF VALVES BETWEEN A GROUP OF ECCS PRESSURIZED TANKS AND REACTOR | IGNALINA-2, Lithuania |
| 21-11-1995 | INES 2 | PERSONNEL OVEREXPOSURE DURING FUEL ASSEMBLY EXTRACTION | KURSK-4, Russian Federation |