| date | INES | title | location |
| 22-09-1992 | INES 1 | SMALL FIRES CAUSED BY SHORT-CIRCUIT | KOZLODUY-5, Bulgaria |
| 12-09-1992 | INES 0 | LOW ACTIVITY WATER LEAK FROM THE CONTAMINATED CONDENSATE TANK | KOLA-3, Russian Federation |
| 08-09-1992 | INES 3 | PLUTONIUM NITRATE LEAK IN CELL | BNFL, Sellafield, United Kingdom |
| 04-09-1990 | INES 1 | REACTOR START UP WITH DEGRADED REACTOR SHUT DOWN SYSTEMS | LEIBSTADT, Switzerland |
| 11-09-1991 | INES 0 | FAILURE OF TWO PRESSURIZER SPRAY LINES | BEZNAU-1, Switzerland |
| 10-04-1992 | INES 0 | LOSS OF AC POWER DURING REFUELING WITH UNLOADED REACTOR | BEZNAU-2, Switzerland |
| 17-08-1992 | INES 0 | CRACKS IN FEED WATER NOZZLES | RINGHALS-1, Sweden |
| 04-06-1992 | INES 1 | INOPERABILITY OF HERMETIC COMPARTMENT PRESSURE INDICATORS OF ESFAS | DUKOVANY-2, Czech Republic |
| 21-08-1992 | INES 2 | ABNORMAL PRESENCE OF A FILTER ON A DRAINING CIRCUIT OF THE REACTOR CAVITY | CATTENOM-1, France |
| 12-08-1992 | INES 0 | UNIT SCRAM DUE TO SHORT-TIME DEENERGIZATION OF AUXILIARY POWER BUSES | KOLA-1, Russian Federation |
| 28-07-1992 | INES 2 | CLOGGED PUMP SUCTION STRAINERS IN THE WET WELL POOL | BARSEBECK-2, Sweden |
| 01-06-1992 | INES 0 | REPAIR OF REACTOR PRESSURE VESSEL HEAD PENETRATION | RINGHALS-2, Sweden |
| 31-01-1992 | INES 2 | DETECTION OF A DESIGN ERROR INTHE LEVEL INSTRUMENTATION IN THE ANNULUS OUTSIDE THE CONTAINMENT SPHERE (BETWEEN THE SPHERE AND THE CONTAINMENT BUILDING) | TRILLO-1, Spain |
| 06-12-1991 | INES 1 | DEVIATION FROM THE NORMAL ON-LOAD REFUELING REGIME DUE TO FUEL ASSEMBLY SEPARATION FROM THE CONNECTING BAR | SMOLENSK-3, Russian Federation |
| 10-06-1992 | INES 1 | CONTAMINATED PARTICLES DISCOVERED ON-SITE | KOZLODUY-1, Bulgaria |
| 19-04-1992 | INES 0 | POWER UNIT UNLOADING DUE TO THE THIRD MAIN CIRCULATION PUMP (MCP-3) TURNING-OFF AS A RESULT OF FALSE OPERATION OF MAJOR PROTECTION SYSTEM | ZAPOROZHE-4, Ukraine |
| 18-03-1992 | [N/A] | NO IMPACT TO SAFETY FOLLOWING RUPTURE OF A BYPASS FEEDWATER LINE | KHMELNITSKI-1, Ukraine |
| 24-03-1992 | INES 2 | UNIT SHUTDOWN DUE TO DEPRESSURIZATION OF ONE FUEL CHANNEL | LENINGRAD-3, Russian Federation |
| 04-03-1992 | INES 0 | UNIT SHUTDOWN DUE TO FIRE IN THE 6 KV SWITCHGEAR ROOM | BALAKOVO-3, Russian Federation |
| 05-02-1992 | [N/A] | STEAM LEAK AT HIGH PRESSURE TURBINE CAP | KRSKO, Slovenia |
| 22-01-1992 | INES 2 | UNAVAILABILITY OF THE IODINE FILTERING OF REACTOR CONTROL ROOM VENTILATION SYSTEM | DAMPIERRE-1, France |
| 29-01-1992 | INES 0 | NO IMPACT ON SAFETY FOLLOWING A FIRE IN THE AUXILIARY BUILING OF UNITS 3 AND 4 | KOZLODUY-3, Bulgaria |
| 30-12-1991 | INES 2 | UNIT SHUTDOWN AS A RESULT OF SPURIOUS OPERATION OF THE FIRE EXTINGUISHING SYSTEM AND DUE TO FLOODING OF ESFAS PANELS | ZAPOROZHE-2, Ukraine |
| 05-01-1992 | INES 0 | NO IMPACT TO SAFETY AFTER IGNITION OF THERMAL INSULATION OF A PIPE IN THE PRIMARY COOLANT SYSTEM | KOZLODUY-5, Bulgaria |
| 10-09-1991 | INES 1 | REVEAL OF INADVERTENTLY CLOSED MANUAL SERVICE VALVES AT VERIFICATION TESTS OF THE SCRAM SYSTEM BEFORE PREPARATIONS TO RESTART | FORSMARK-2, Sweden |
| 07-12-1991 | INES 0 | DAMAGE TO RCP MAIN THRUST BEARING WHILE PREPARING PRIMARY FOR HYDROTEST | KOLA-3, Russian Federation |
| 18-09-1991 | INES 1 | ONE FUEL ASSEMBLY TILTED DURING REFUELLING | RINGHALS-4, Sweden |
| 22-07-1991 | INES 3 | BREACH OF UNIT LIMITING CONDITIONS FOR OPERATION WHILE PREPARING FOR RESTART AFTER MAINTENANCE DUE TO ECCS AND MSV UNAVAILABILITY | SMOLENSK-2, Russian Federation |
| 25-10-1991 | INES 2 | BORATED WATER STORAGE TANK LEVEL REDUCTION TO 180 M3 | NOVOVORONEZH-4, Russian Federation |
| 23-09-1991 | INES 2 | DEFECTS IN BUGEY AND FESSENHEIM POWER PLANT REACTOR VESSEL HEADS | BUGEY-2, France |